Monitor BS Indirect Tank Techs & Specs

Applications and sizing
Models   BS 25 BS 40 BS 50 BS 80
Nominal Storage Gal. 25 40 50 80
Height Inches 27.5" 36.4" 45.3" 63"
Diameter Inches 23.6" 23.6" 23.6" 23.6"
All Pipe Connections MPT 3/4" 3/4" 3/4" 3/4"
Max DHW Pressure PSI 100 100 100 100
Aquastat Range F 68-176ºF 68-176ºF 68-176ºF 68-176ºF
Aquastat Differential F 10.8ºF 10.8ºF 10.8ºF 10.8ºF
Inspection Port Opening Inches 3.9" 3.9" 3.9" 3.9"
Nominal Exchanger Power (170ºF Av. Boiler Water Temp) MBH 115 115 200 210
Nominal Reheat Time from 50ºF to 140ºF Stored MIN. 10 15 12 17
Continuous Output at 110ºF GPM 3.8 3.8 6.5 6.7
Nominal First Hour Draw at 70ºF Rise GAL. 250 260 430 465
Dry Weight LBS. 71 86 121 159
Ratings assume cold-water inlet at 50ºF, boiler circuit average temp of 170ºF and
boiler output at least equal to the nominal heat exchanger power shown above.




Monitor BS Indirect Tanks

A. 316 L austenitic stainless steel tank
B. 316 L austenitic stainless steel tank
C. Molded, rigid removable insulation
D. Removable ABS plastic casing
E. DHW cold inlet
F. DHW hot outlet
G. Boiler circuit inlet
H. Boiler circuit outlet
I. Pressure-temperature relief tap and/or DHW recycling circuit tap
J. Inspection opening
K. Thermometer
L. Aquastat